Air Conditioning - A Career That Offers Plenty

By: Marcus Sen

Today’s world offers a gamut of career options. You can take your career towards several directions. While the choice is yours, make sure you choose the right track that suits your strengths. Amidst the flurry of career options, one of the hottest & most happening jobs in the world is in the field of air conditioning and refrigeration.

Like most other engineering disciplines, it takes a specific kind of college degree and job training in order to be able to work successfully in the industry. And for that you need to join an air conditioning training without any further delay.

In an air condition course, you get to learn about topics such as the purpose and function of refrigeration, the equipment, basic definitions and SI units, pressure, temperature, sensible, latent & enthalpy, heat transfer, heat load calculation & so on. An engineer in this field also has to be well versed with installation, maintenance, servicing and repair & should learn to work in varied environments like, industrial, residential and commercial. Air conditioning & refrigeration has a wide prospect & skilled workers are always in demand.

After you become a specialist in the field, you can enjoy great career options like air conditioning & refrigeration contractors, consultants, manufacturers of all types of equipment including air conditioning, refrigeration and humidity control products, compressors and components. The refrigeration industry, just like any other field is also evolving fast. So, if you want a career that pays well, challenges your brain, and requires you to learn something new all the time - consider the ever evolving science of refrigeration. There are several institutes providing specialised training to those who wish to pursue a career in this field.



The institute you choose must provide sound theoretical and practical training & must be recognised for its service. Institutes extending education alongside comprehensive training modules covering basic as well as advanced concepts and technologies are always to be preferred. Only a structured and well monitored training program can prepare skilled technicians for an ever-evolving industry that air conditioning and refrigeration is.

Hence, what makes one better than others is the training process. A good engineer is backed by proper training & sound knowledge. Join an air conditioning school that is capable of providing you the required knowledge.

About the Author

The article is contributed by a professional content writer, having experiences of working in different industries. For further information on air conditioning & refrigeration and air conditioning and refrigeration courses please visit http://www.businessedgeltd.co.uk/

(ArticlesBase SC #1861109)

Article Source: http://www.articlesbase.com/ - Air Conditioning - A Career That Offers Plenty



Ultimatum MediaPartager




Shanny Fournier
President






Tel:418.849.0101
Cel:418.803.6682
Ultimatum Media inc.


mardi 8 juin 2010

Carbon Dioxide Could Replace Global-Warming Refrigerant




ScienceDaily (July 4, 2000) — WEST LAFAYETTE, Ind. – Researchers are making progress in perfecting automotive and portable air-conditioning systems that use environmentally friendly carbon dioxide as a refrigerant instead of conventional, synthetic global-warming and ozone-depleting chemicals.

It was the refrigerant of choice during the early 20th century but was later replaced with manmade chemicals. Now carbon dioxide may be on the verge of a comeback, thanks to technological advances that include the manufacture of extremely thin yet strong aluminum tubing.

Engineers will discuss their most recent findings from July 25 to 28, during the Gustav Lorentzen Conference on Natural Working Fluids, one of three international air-conditioning and refrigeration conferences to be held concurrently at Purdue University. Unlike the two other conferences, the biannual Gustav Lorentzen Conference, which is being held for the first time in the United States, focuses on natural refrigerants that are thought to be less harmful to the environment than synthetic chemical compounds.

"The Gustav Lorentzen Conference focuses on substances like carbon dioxide, ammonia, hydrocarbons, air and water, which are all naturally occurring in the biosphere," says James Braun, an associate professor of mechanical engineering at Purdue who heads the organizing committee for all three conferences. "Most of the existing refrigerants are manmade."

Purdue engineers will present several papers detailing new findings about carbon dioxide as a refrigerant, including:

• Creation of the first computer model that accurately simulates the performance of carbon-dioxide-based air conditioners. The model could be used by engineers to design air conditioners that use carbon dioxide as a refrigerant. A paper about the model will be presented on July 26 during a special session sponsored by the U.S. Army in which researchers from several universities will present new findings.

• The design of a portable carbon-dioxide-based air conditioner that works as well as conventional military "environmental control units." Thousands of the units, which now use environmentally harmful refrigerants, are currently in operation. The carbon dioxide unit was designed using the new computer model. A prototype has been built by Purdue engineers and is being tested.

• The development of a mathematical "correlation," a tool that will enable engineers to design heat exchangers – the radiator-like devices that release heat to the environment after it has been absorbed during cooling – for future carbon dioxide-based systems. The mathematical correlation developed at Purdue, which will be published in a popular engineering handbook, enables engineers to determine how large a heat exchanger needs to be to provide cooling for a given area.

• The development of a new method enabling engineers to predict the effects of lubricating oils on the changing pressure inside carbon dioxide-based air conditioners. Understanding the drop in pressure caused by the oil, which mixes with the refrigerant and lubricates the compressor, is vital to predicting how well an air conditioner will perform.

Although carbon dioxide is a global-warming gas, conventional refrigerants called hydrofluorocarbons cause about 1,400 times more global warming than the same quantity of carbon dioxide. Meanwhile, the tiny quantities of carbon dioxide that would be released from air conditioners would be insignificant, compared to the huge amounts produced from burning fossil fuels for energy and transportation, says Eckhard Groll, an associate professor of mechanical engineering at Purdue.

Carbon dioxide is promising for systems that must be small and light-weight, such as automotive or portable air conditioners. Various factors, including the high operating pressure required for carbon-dioxide systems, enable the refrigerant to flow through small-diameter tubing, which allows engineers to design more compact air conditioners.

More stringent environmental regulations now require that refrigerants removed during the maintenance and repair of air conditioners be captured with special equipment, instead of being released into the atmosphere as they have been in the past. The new "recovery" equipment is expensive and will require more training to operate, important considerations for the U.S. Army and Air Force, which together use about 40,000 portable field air conditioners. The units, which could be likened to large residential window-unit air conditioners, are hauled into the field for a variety of purposes, such as cooling troops and electronic equipment.

mercredi 2 juin 2010

Evaporator, Compressor & Condenser

The Evaporator

The purpose of the evaporator is to remove unwanted heat from the product, via the liquid refrigerant. The liquid

refrigerant contained within the evaporator is boiling at a low-pressure. The level of this pressure is determined by two

factors:

- The rate at which the heat is absorbed from the product to the liquid refrigerant in the evaporator

- The rate at which the low-pressure vapour is removed from the evaporator by the compressor

To enable the transfer of heat, the temperature of the liquid refrigerant must be lower than the temperature of the product

being cooled. Once transferred, the liquid refrigerant is drawn from the evaporator by the compressor via the suction line.

When leaving the evaporator coil the liquid refrigerant is in vapour form.



The Compressor

The purpose of the compressor is to draw the low-temperature, low-pressure vapour from the evaporator via the suction

line. Once drawn, the vapour is compressed. When vapour is compressed it rises in temperature. Therefore, the

compressor transforms the vapour from a low-temperature vapour to a high-temperature vapour, in turn increasing the

pressure. The vapour is then released from the compressor in to the discharge line.

The Condenser

The purpose of the condenser is to extract heat from the refrigerant to the outside air. The condenser is usually installed

on the reinforced roof of the building, which enables the transfer of heat. Fans mounted above the condenser unit are

used to draw air through the condenser coils.

The temperature of the high-pressure vapour determines the temperature at which the condensation begins. As heat has

to flow from the condenser to the air, the condensation temperature must be higher than that of the air; usually between -

12°C and -1°C. The high-pressure vapour within the condenser is then cooled to the point where it becomes a liquid

refrigerant once more, whilst retaining some heat. The liquid refrigerant then flows from the condenser in to the liquid line.

Source: http://www.europe.honeywell.com/70_refrigeration_control/EN5B-0024UK07%20R0505.pdf

jeudi 27 mai 2010

Vapour Compression Cycle

The Minimum Amount of Work to Drive a Heat Pump is defined in terms of the Absolute Temperature Scale

Here we show again the diagram that was used to help explain the Reversible Carnot Cycle. It shows a reversible engine E driving a reversible heat pump P. The relationship between Q1, Q2 and W depends only on the temperatures of the hot and cold reservoirs, just as Carnot predicted. But temperature must be defined in a more fundamental way. The degrees on the thermometer are only an arbitrary scale. Kelvin took the bold step in 1851 of defining an absolute temperature scale in terms of the efficiency of reversible engines:

The ideal "never attainable" efficiency is the ratio of work output to heat input (W/Q1) of the reversible engine E and it equals: Temperature Difference (T1 - T0) divided by the Hot Reservoir Temperature (T1). It is known as the Carnot efficiency, taking its name from Sadi Carnot.

The device P can be any refrigeration device we care to invent, and the work of Kelvin tells us that the Minimum Work, W necessary to lift a quantity of heat Q2 from temperature T0 to temperature T1 is:

Q2 multiplied by the ratio Temperature Difference (T1 - T0)/Cold Reservoir Temperature (T0). The temperatures must be measured on an Absolute scale.

Choose a fluid, or refrigerant, which vaporizes at a lower temperature than the space to be cooled. Heat then flows from the cool space (downhill) and vaporizes the refrigerant. This is represented by the section 1 - 2 of the orange line. Then, instead of just letting it boil away and disappear as vapour, it is captured, and pressurized (2 - 3). At the high pressure its boiling point, or evaporating temperature is much higher. So it can condense at this higher temperature, giving up its latent heat which flows (downhill again) to the warm air outside (3 - 4). When it has become a liquid, the pressure is reduced (4 - 1) and the process can start again.

This is the most widely used process for providing cooling. It is called the Vapour Compression Cycle, and it finds application on equipment ranging from domestic refrigerators and freezers to large cold stores and building air conditioning systems.

Pressure - Enthalpy

In order to study this process more closely, refrigeration engineers use this pressure - enthalpy diagram. "P" is the symbol for Pressure, and "h" is the symbol for Enthalpy. This diagram is a way of describing the liquid and gas phase of a substance. On the vertical axis is pressure, and on the horizontal, enthalpy. Enthalpy can be thought of as the quantity of heat in a given quantity, or mass of substance. The curved line is called the saturation curve and it defines the boundary of pure liquid and pure gas, or vapour. In the region marked vapour, its pure vapour. In the region marked liquid, its pure liquid. If the pressure rises so that we are considering a region above the top of the curve, there is no distinction between liquid and vapour. Above this pressure the gas cannot be liquified. This is called the Critical Pressure. In the region underneath the curve, there is a mixture of liquid and vapour.


mardi 11 mai 2010

Simulation model of a low-temperature supermarket refrigeration system.


HVAC & R Research

| October 01, 2006 | Getu, Haile-Michael; Bansal, Pradeep Kumar | COPYRIGHT 2008 American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. This material is published under license from the publisher through the Gale Group, Farmington Hills, Michigan. All inquiries regarding rights should be directed to the Gale Group. (Hide copyright information)Copyright

This paper presents a computer simulation model of a low-temperature supermarket refrigeration system whose main components include a compressor, a display cabinet, a condenser, and a thermostatic expansion valve. The energy consumption of the system was evaluated as a function of the store relative humidity, which was measured every 16 seconds for 15 days. The model results were validated with the measurements taken from a representative in-situ supermarket in Auckland, New Zealand. The simulation results indicated that the rate of heat transfer in the evaporator was reduced by nearly 10.5 W for each 1% increase in daily average store relative humidity due to the insulating effect of the frost. The frost thickness was found to grow at 0.0354 mm for each 1% increase in the daily average store relative humidity over a 12 hour operation period between the defrost cycles. The pressure drop of the air over the evaporators increased by around 12 Pa for every 10% rise in the daily average store relative humidity.

INTRODUCTION

Supermarkets, which contain heating, cooling, and ventilation (HVAC) as well as refrigeration systems, are the most energy-consuming commercial establishments (Mei et al. 2002). According to the real measurements in the current study, the average power consumption of compressors/rack systems for both the low- and medium-temperature refrigeration systems of the supermarket amounts to roughly 20% of the total energy use. The energy consumption due to auxiliary equipment (defrosting, anti-sweat resistance heaters, display cabinet lights, and fans) and the air-conditioning system of the building are, respectively, 14% and 17%, while the remaining 49% is attributed to water, heating, and lighting systems of the establishment. Defrosting of evaporator coils is one of the most energy-consuming processes in supermarket refrigeration systems. A large amount of frost accumulation decreases the performance of the coil due to reduced rate of heat transfer and airflow. This consequently reduces the refrigerating capacity of the evaporator. Hence, frosting needs attention and should be minimized to improve the energy efficiency of the system and temperature control.

The impact of store relative humidity on refrigerated display case performance has been studied by Howell (1993a, 1993b), Orphelin et al. (1997), and Henderson and Khattar (1999), where the possible energy savings were predicted by reducing the store relative humidity and the energy penalty realized by the air-conditioning system. Among other studies by Inlow and Groll (1996), McDowell et al. (1995), Horton (2002), and Walker and Baxter (2003) on supermarket refrigeration systems, Ge and Tassou (2000) have presented a mathematical model for direct expansion supermarket refrigeration systems using TRNSYS (2001). Their display cabinet model, however, was quite restricted and used loads only due to infiltration, conduction, convection, and radiation, and the model was validated only for medium-temperature display cabinets. The simulation and the experimental work carried out so far in the supermarket industry has mainly focused on medium-temperature refrigeration systems. Further, dynamic frosting, as a result of store relative humidity, is ignored except in the medium-temperature cabinet models of Ge and Tassou (2000). Therefore, there is a need to develop a complete simulation model for low-temperature supermarket refrigeration systems, since they are most affected by the store relative humidity. This paper, therefore, presents a numerical model to investigate the performance of in-situ low-temperature display cases as a function of store relative humidity. The model includes major components of the refrigeration system, such as compressors, display cabinets, condensers, and thermostatic expansion valves. Specific correlations were used to compute frost thickness, rate of heat transfer across the evaporators, and COP. The model results were validated against the measurements taken from an in-situ supermarket located in Auckland, New Zealand, from December 1, 2004, to January 10, 2005. The model was written in a software package called Engineering Equation Solver, or EES (2004), which has built-in properties of many refrigerants. The computer model can be used as a convenient tool to accurately calculate the energy savings of the low-temperature refrigeration systems as a function of store relative humidity.

THE LOW-TEMPERATURE SUPERMARKET REFRIGERATION SYSTEM

Supermarkets have three different types of cooling systems. The first one is the air-conditioning system, whose operating temperature is roughly 5[degrees]C, which regulates the relative humidity and temperature in the occupied store. The second one is the medium-temperature refrigeration system. It has an evaporation temperature of around -8[degrees]C and provides refrigeration for fresh food such as meats, vegetables, and dairy products. The third system has an evaporation temperature down to -40[degrees]C and is called the low-temperature refrigeration system. Nowadays, there are various types of refrigeration systems, such as direct expansion/multiplex, secondary-loop, distributed, and cascade refrigeration systems. However, the direct expansion refrigeration system is the most commonly employed configuration in most supermarkets for providing refrigeration to display cabinets located in the store.

The low-temperature direct expansion refrigeration system under consideration (see Figure 1) consists of display cabinets/freezer rooms of varying geometry, multiple compressors, air-cooled condensers, thermostatic expansion valves (type DANFOSS TUA/TUAE), and evaporator pressure regulating valves (EPRVs). The function of EPRVs, as presented by Tahir and Bansal (2005), is to keep the evaporating temperatures of the respective display cabinet/freezer room at the required levels. The pressure and temperature at the suction manifold of the compressors are also determined by these valves. The dotted line enclosure shown in Figure 1 contains the evaporator assemblies, including drain points for condensate collections during defrost periods. These components in the enclosure are located within the bottom parts of the display cabinets and on the walls of the freezer rooms.

The low-temperature refrigeration system (Figure 1) consists of three major circuits that feed refrigerant R-404A to three sections of the supermarket, such as frozen food cabinets, fish/meat cabinets, and freezer rooms. The geometrical parameters and the operating temperatures of each type of cabinet and freezer room are given in Table 1.

DEVELOPMENT OF SIMULATION MODEL

The development of the simulation model for a low-temperature supermarket refrigeration system, which includes major components such as compressors, display cabinets, condensers, and thermostatic expansion valves, is discussed in the following sections.

Compressor Model

Multiple compressors (rack) in a supermarket refrigeration system are mostly of the semi-hermetic reciprocating type. If the compressor performance data are known, the compressor model may be developed based on the philosophy presented by Popovic and Shapiro (1995). Their model requires inputs such as refrigerant inlet state, outlet refrigerant pressure, clearance volume, polytropic exponents for specific refrigerants, and motor speed to calculate refrigerant mass flow rate and refrigerant.


lundi 10 mai 2010

China Refrigeration: Walking on the CO2 path - Part I

The world’s third largest trade show for heating and cooling was, as expected, dominated by solutions for conventional refrigerants. However, a surprising number of global players presented CO2 components set to be sold on the Chinese market in a few years time. In a technical seminar, Bitzer updated Chinese experts on latest developments regarding CO2 compressors.

At the China Refrigeration, held last week from 5-7 April in Guangzou, companies known to be involved in CO2, nearly animously agreed that the natural refrigerant would certainly be a solution to be taken to the Chinese market in the near future. At present however, and also looking at cost cutting tendencies in the industry, CO2 would remain mainly in the testing phase, with commercialisation to be expected over the next few years.

Technical Seminar on CO2 compressors

In its technical presentation to around 100 industry experts and engineers, German compressor manufacturer Bitzer updated on the performance and operation of its CO2 range. In a packed room, Bitzer representatives from China started off by explaining basic characteristics of R744, its behaviour compared to R22 or R404a, differences between transcritical and subcritical operation, and the compact design of CO2 compressors. The compressor maker then went on to elaborate on the different system layouts used with R744, specific design options, and efficiency comparisons between the natural and chemical refrigerants.

Participants were highly interested in technical details regarding high-pressure R744 systems. Lively discussions centred around the questions of oil return, the materials used for CO2 compressors, the preferred hybrid systems used in European supermarkets, and better cooling systems in a Chinese test system using R404a-R744.


vendredi 7 mai 2010

Ice as a refrigeration Agent

As time went on, ice, as a refrigeration agent, became a health problem. Says Bern Nagengast, co-author of Heat and Cold: Mastering the Great Indoors (published by the American Society of Heating, Refrigeration and Air-conditioning Engineers), “Good sources were harder and harder to find. By the 1890’s, natural ice became a problem because of pollution and sewage dumping.” Signs of a problem were first evident in the brewing industry. Soon the meatpacking and dairy industries followed with their complaints. Refrigeration technology provided the solution: ice, mechanically manufactured, giving birth to mechanical refrigeration.
Carl (Paul Gottfried) von Linde in 1895 set up a large-scale plant for the production of liquid air. Six years later he developed a method for separating pure liquid oxygen from liquid air that resulted in widespread industrial conversion to processes utilizing oxygen (e.g., in steel manufacture).

Though meat-packers were slower to adopt
refrigeration than the breweries, they ultimately used refrigeration pervasively. By 1914, the machinery installed in almost all American packing plants was the ammonia compression system, which had a refrigeration capacity of well over 90,000 tons/day.

Despite the inherent advantages, refrigeration had its problems. Refrigerants like sulfur dioxide and methyl chloride were causing people to die. Ammonia had an equally serious toxic effect if it leaked.
Refrigeration engineers searched for acceptable substitutes until the 1920s, when a number of synthetic refrigerants called halocarbons or CFCs (chlorofluorocarbons) were developed by Frigidaire. The best known of these substances was patented under the brand